Provide Complete Tooth Replacement to Your Patients
Our leading TS System for dental implants has become one of the best dental implant systems in the industry because of our commitment to extensive research and the creation of a high-quality, safe and innovative implant. Implants from our TS System have received recognition from the CR Foundation as well as Dentistry Today in New Zealand.
Its design eliminates unnecessary steps so surgery is shorter and easier, and the build of our titanium dental implant systems makes mastery simple.
Use this implant pre-mounted, as well as with mini 3.5 connection abutments.
TSIII SA
Our most popular implant includes four different diameters in no-mount and pre-mounted configurations.
TSIII BA (ETIII NH)
This single tooth dental implant features a bio-resorbable apatite coating with high hydrophilic properties. Research shows it improves bone-to-implant contact (BIC) by 39 percent.
Every TS System dental implant has a Sand-blasted and Acid-etched (SA) surface to give you optimal morphology. This feature improves the available surface area by 45 percent, in comparison to a Resorbable Blast Media (RBM) surface. Additional advantages include bones healing 20 percent faster and a decrease in loading times.
TSIII 3.0
Conventional Implant for Restrictive Spaces
Our TSIII 3.0 Implant provides a strong, mini-solution for needing a fixture with a smaller diameter. As a member of our TS System, this implant features our Sand-blasted and Acid-etched (SA) surface, as well as our bio-compatible titanium build.
With our TSIII BA Implant, you and your patients are given several benefits due to its unique nanolayer of bio-resorbable apatite coating, which has super hydrophilic properties.
As an TSIII Implant, the 3.0 model shares many of the advantages of our award-winning TSIII SA Implant.
Developed by the Osstem Implant research team, benefits of this implant and its mini-fixture include :
Small thread for increased self-threading power, path-correction and initial stability in soft bone.
Straight body for raised implantation performance.
SA surface for 45% increase in morphology and surface roughness.
Hermetic seal for reduced percolation of saliva and bacteria.
Extensive tests by our research and development team also demonstrate the advantage of our TSIII 3.0 Implant when compared to implants with a Resorbable Blast Media (RBM) surface:
A 45 percent improvement in the surface area.
A 20 percent decrease in bone healing times.
A 20 percent decrease in cell response times.
TSIII SA
Winner of Dentistry Today’s Readers’ Choice and Top 100 Products Award in America
Our TSIII SA Implant — winner of Dentistry Today’s Readers’ Choice and Top 100 Products Award in America — features the TS System’s signature Sand-blasted and Acid-etched (SA) surface, plus a bio-compatible titanium build. Designed by our research and development team at Osstem Implant, this implant meets our unparalleled standards for safety, quality, and effectiveness.
With our TSIII SA Implant, which includes an 11-degree Morse taper connection, you and your patients receive many benefits due to the submerged fixture’s design features, which stem from extensive research and testing.
Benefits of the TSIII SA Implant
Small thread for increased self-threading power, path-correction and initial stability in soft bone.
Straight body for raised implantation performance.
SA surface for 45% increase in morphology and surface roughness.
Hermetic seal for reduced percolation of saliva and bacteria.
The open thread design of our TSIII SA Implant ensures your patient’s safety by preventing bone necrosis. Research also demonstrates that our SA implants offer a competitive advantage over Resorbable Blast Media (RBM) implants by improving cell response and bone healing times by 20%.
With its optimal body design, placement of this implant is simple to learn and master. It also provides your patients with shorter surgery and recovery times, as well as a safe and effective outcome.
TSIII BA (ETIII NH)
Our TSIII BA Implant from our TS System builds on the line’s Sand-blasted and Acid-etched (SA) surface combined with a unique bioresorbable apatite Nano Coating that helps ensure optimal treatment outcomes with every implant you place. Produced by our in-house research and development team, this implant continues our goal of providing safe, effective and high-quality implants to dentists across the globe.
With our TSIII BA Implant, you and your patients are given several benefits due to its unique nanolayer of bio-resorbable apatite coating, which has super hydrophilic properties.
Benefits of this nano-coated implant surface — compared to an SA implant — and hydrophilic traits include:
A 39% improvement in bone-to-implant contact (BIC).
A 12% increase in platelet adhesion.
A more than 30% improvement on osseointegration.
A 12% increase in cell differentiation.
Because the TSIII BA Implant improves osseointegration, it also boosts healing times. This increase builds on the ability of our SA implants in the TS System, which provides a 20% faster bone healing time than implants with a Resorbable Blast Media (RBM) surface.